0.6/1kv Single Core XLPE Insulation PVC Bedded Aluminium Wire Armour PVC Sheath Power Cable

0.6/1kv Single Core XLPE Insulation PVC Bedded Aluminium Wire Armour PVC Sheath Power Cable

 

CU/XLPE/PVC/AWA/PVC (Single Core)
XLPE Insulated, PVC Bedded, Alminium Wire Armoured, PVC Sheathed Cable

 

Application

These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.

1core insulation sheath awa sheath

Construction

Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228.
                 Flexible class 5 or tinned conductor could be offer upon request.
Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1.
Insulation Color Code:

Number of Cores Color Code to IEC 60502-1 Color Code to BS 5467
1 Red or Black Brown or Blue

Bedding: Polyvinyl choride (PVC) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1.
Bedding Colour: Black or other color as per customer request.
Armour: Aluminium wire armoured (AWA).
Outer Sheath: Polyvinyl choride (PVC) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1.
Outer Sheath Color: Black or other color as per customer request.

 

Electrical Characteristics

Recommended rated voltages U0

Highest system voltage
(Um) (kV)
Rated voltage (U0) (kV)
Categories A and B Category C
1,2 0,6 0,6

Routine test voltages

Rated voltage U0 (kV) 0,6
Test voltage (kV) 3,5

Maximum conductor temperatures for different types of insulating compound

Maximum conductor temperature (°C)
Normal operation Short-circuit (5 s maximum duration)
90 250

Operating Temperature: -15°C to 90°C
Test Voltage: 3.5 kV for 5 minutes

 

Installation Reference

Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm2): 50

 

Reference Standards

Design Specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-1, BS EN60332-1

 

Dimension

Nominal Conductor Area
(mm2)
No,and Diameter of Wires
(no./mm)
Thickness of Insulation
(mm)
Thickness of Bedding
(mm)
Diameter of Armour Wire
(mm)
Thickness of Sheath
(mm)
Overall Diameter
(mm)
Approximate Weight
(kg/km)
1x50 19/1.78 1 1 1.25 1.8 19 1086
1x70 19/2.14 1.1 1 1.25 1.8 21 1387
1x95 19/2.52 1.1 1 1.6 1.8 23.6 1881
1x120 37/2.03 1.2 1 1.6 1.8 25.4 2227
1x150 37/2.25 1.4 1 1.6 1.8 27.4 2611
1x185 37/2.52 1.6 1 1.6 1.9 29.8 3132
1x240 61/2.25 1.7 1 2 2 33.7 4131
1x300 61/2.52 1.8 1.2 2 2.1 36.9 4988
1x400 61/2.85 2 1.2 2 2.2 40.5 6091
1x500 61/3.20 2.2 1.2 2.5 2.4 45.4 7823
1x630 127/2.52 2.4 1.4 2.5 2.5 50.4 9702
1x800 127/2.85 2.6 1.4 2.5 2.7 55.5 11924
1x1000 127/3.20 2.8 1.6 2.5 2.9 61.2 14606

 

downloadpdf