Application
These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.

Construction
1 Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228.
Flexible class 5 or tinned conductor could be offer upon request.
2 Insulation: Polyviny chloride (PVC) compound as per IEC 60502-1.
Insulation Color Code:
| Number of Cores | Color Code to IEC 60502-1 | Color Code to BS 5467 |
| 1 | Red or Black | Brown or Blue |
3 Bedding: Polyvinyl choride (PVC) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1.
4 Armour: Aluminium wire armoured (AWA).
5 Outer Sheath: Polyvinyl choride (PVC) compound type ST1 (80°C), ST2 (90°C) of IEC 60502-1.
Outer Sheath Color: Black or other color as per customer request.
Electrical Characteristics
Recommended rated voltages U0
| Highest system voltage | Rated voltage (U0) (kV) | |||||||
| (Um) (kV) | Categories A and B | Category C | ||||||
| 1,2 | 0,6 | 0,6 | ||||||
| Routine test voltages | ||||||||
| Rated voltage U0 (kV) | 0,6 | |||||||
| Test voltage (kV) | 3,5 | |||||||
| Maximum conductor temperatures for different types of insulating compound | ||||||||
| PVC Insulation compound | Maximum conductor temperature (°C) | |||||||
| Normal operation | Short-circuit (5 s | |||||||
| maximum duration) | ||||||||
| Conductor cross-section ≤300 mm2 | 70 | 160 | ||||||
| Conductor cross-section >300 mm2 | 70 | 140 | ||||||
Minimum Insulation Resistance at 20°C: 36.7 MΩ·km
Operating Temperature: -15°C to 70°C
Test Voltage: 3.5 kV for 5 minutes
Installation Refference
Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm2): 50


