| Standards: | JISC 3410-1999 IEC 60332-1 IEC 60332-3 Cat.A(for FA-type) | 

CABLE CONSTRUCTION
| Conductor | M | Tinned annealed stranded copper, class 2 according to IEC 60228 | 
| Insulation | P | 85°C EPR as per JIS C 3401 | 
| Cabling | Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used | |
| Overall shield | S | Tinned copper wire braid | 
| Bedding | Y | PVC as per JIS C 3401 | 
| Armor | C | Galvanized steel wire braid | 
| Sheath | Y | PVC as per JIS C 3401 | 
| Core identification | Black No. on white insulation | |
| Outer sheath color | Black | 
Cable Parameter
250V (FA-) MPYS
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | (FA-) MPYS | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 9.4 | 0.4 | 135 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 10.6 | 0.5 | 190 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.2 | 12.6 | 0.6 | 270 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.3 | 16.3 | 0.7 | 430 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.5 | 19.3 | 0.8 | 600 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.6 | 23 | 1 | 840 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.7 | 25.7 | 1.1 | 1070 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.8 | 28.9 | 1.2 | 1290 | 
250V (FA-) MPYCS
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. of steel wire | (FA-) MPYCS | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 0.3 | 10.7 | 0.4 | 205 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 0.3 | 11.9 | 0.5 | 260 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.2 | 0.3 | 13.9 | 0.6 | 355 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.3 | 0.3 | 17.6 | 0.7 | 540 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.5 | 0.3 | 20.6 | 0.8 | 735 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.6 | 0.3 | 24.3 | 1 | 995 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.7 | 0.3 | 27 | 1.1 | 1240 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.8 | 0.3 | 30.2 | 1.2 | 1480 | 
250V (FA-) MPYCYS
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) MPYCYS | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 0.3 | 0.9 | 12.7 | 0.5 | 255 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.1 | 0.3 | 0.9 | 13.9 | 0.6 | 315 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.14 | 1.2 | 0.3 | 0.9 | 15.9 | 0.6 | 420 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.3 | 0.3 | 1 | 19.8 | 0.8 | 625 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.16 | 1.5 | 0.3 | 1.1 | 23 | 0.9 | 850 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.6 | 0.3 | 1.2 | 26.9 | 1.1 | 1140 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.7 | 0.3 | 1.3 | 29.8 | 1.2 | 1410 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.18 | 1.8 | 0.3 | 1.4 | 33.2 | 1.3 | 1680 | 

 
	