| Standards: | JISC 3410-1999 IEC 60332-1 IEC 60332-3 Cat.A(for FA-type) | 

CABLE CONSTRUCTION
| Conductor | M | Tinned annealed stranded copper, class 2 according to IEC 60228 | 
| Insulation | P | 85°C EPR as per JIS C 3401 | 
| Individual shield | -S | Tinned copper wire braid | 
| Cabling | Insulated conductors shall be cabled. Flame retardant & non-hygroscopic fillers may be used | |
| Bedding | Y | PVC as per JIS C 3401 | 
| Armor | C | Galvanized steel wire braid | 
| Sheath | Y | PVC as per JIS C 3401 | 
| Core identification | Black No. on white insulation | |
| Outer sheath color | Black | 
Cable Parameter
250V (FA-) MPY-S
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | (FA-) MPY-S | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | ||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 9.9 | 0.4 | 150 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 11.6 | 0.5 | 230 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 13.9 | 0.6 | 350 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 18.2 | 0.8 | 570 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 21.5 | 0.9 | 840 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 26 | 1.1 | 1200 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 29.2 | 1.2 | 1600 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 33.2 | 1.4 | 2000 | 
250V (FA-) MPYC-S
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. of steel wire | (FA-) MPYC-S | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | |||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 0.3 | 11.2 | 0.4 | 210 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 0.3 | 12.9 | 0.5 | 300 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 0.3 | 15.2 | 0.6 | 435 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 0.3 | 19.5 | 0.8 | 685 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 0.3 | 22.8 | 0.9 | 980 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 0.3 | 27.3 | 1.1 | 1360 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 0.3 | 30.5 | 1.2 | 1760 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 0.4 | 35 | 1.4 | 2240 | 
250V (FA-) MPYCY-S
| No. of cores | Conductor | Thick. of insulation | Dia. of shield wire | Thick. of bedding | Dia. of steel wire | Thick. of covering | (FA-) MPYCY-S | ||||
| Size | Construction | O.D | Nom. overall dia | Tolerance | Cable Weight | ||||||
| mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
| 2 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.1 | 0.3 | 0.9 | 13.2 | 0.5 | 260 | 
| 4 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.2 | 0.3 | 0.9 | 14.9 | 0.6 | 360 | 
| 7 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.3 | 0.3 | 1 | 17.4 | 0.7 | 515 | 
| 12 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.4 | 0.3 | 1.1 | 21.9 | 0.9 | 795 | 
| 19 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.5 | 0.3 | 1.2 | 25.4 | 1 | 1120 | 
| 27 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.7 | 0.3 | 1.3 | 30.1 | 1.2 | 1540 | 
| 37 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 1.8 | 0.3 | 1.4 | 33.5 | 1.3 | 1970 | 
| 44 | 1 | 7/0.43 | 1.29 | 0.7 | 0.12 | 2 | 0.4 | 1.5 | 38.4 | 1.5 | 2500 | 

 
	