Flame Retardant CAT6 CWB/SWB/SWA Armoured Data Cables

CAT6 U/UTP4P23
CAT6 F/UTP4P23
CAT6 SF/FTP4P23

Flame Retardant CAT6 CWBSWBSWA Armoured Data Cables

Application:

Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables can be offered with copper wire braid armoured & flame retardant outer sheath, providing additional mechanically protection still maintaining the flexibility of the cable.

STANDARDS: Basic design adapted to EN50173

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

VOLTAGE RATING

60V

CABLE CONSTRUCTION

Conductors: 23AWG solid bare copper.

Insulation: HDPE.

Twinning: Two coloured insulated conductors twisted together to form a pair.

Inner Sheath: Flame retardant, low smoke and halogen-free polyolefin, coloured black.

Armouring:

cwb: copper Wire Braid

swb: Steel Wire

Braid swa: Steel Wire Armour

Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.

Cat6 F/UTP: These cables have collective shielding of aluminium/Polyester tape with drain wire.

Cat6 SF/UTP: These cables have double collective shieldings of aluminium/Polyester tape & copper wire braid with drain wire.

Physical AND THERMAL PROPERTIES

Temperature range: -30°C ~ +75°C

Minimum bending radius during installation (mobile state): 8 x Overall Diameter

Minimum bending radius during operation (fixed state): 4 x Overall Diameter

Electrical Properties

AWG   23
Nominal Conductor Diameter mm 0.56/0.57/0.58
Maximum DC Resistant@20°C Ω/100m 9.38
Maximum DCR Unbalance % 3
Maximum Mutual Capacitance pF/m 5.8
Maximum Capacitance Unbalance pF/100m 30
Characteristic Impedance@1-100MHz Ω 100+/-15
Maximum Propagation Delay Skew ns/100m 18

Transmission Properties

FREQ MHz Maximum Attenuation dB/100m Minimum NEXT dB Minimum PSNEXT dB Minimum ELFEXT dB/100m Minimum PSELFEXT dB/100m Minimum RL dB
0.772 1.8 76.0 74. 70.0 67.0
1 2.0 74.3 72.3 67.8 64.8 20.0
4 3.8 65.3 63.3 55.7 52.7 23.0
8 5.3 60.8 58.8 49.7 46.7 24.5
10 6.0 59.3 57.3 47.8 44.8 25.0
16 7.6 56.3 54.3 43.7 40.7 25.0
20 8.5 54.8 52.8 41.7 38.7 25.0
25 9.5 53.3 51.3 39.8 36.8 24.3
31.25 10.7 51.9 49.9 37.9 34.9 23.6
62.5 15.4 47.4 45.4 31.8 28.8 21.5
100 19.8 44.3 42.3 27.8 24.8 20.1
155 25.2 41.5 39.5 23.9 20.9 18.8
200 29.0 39.8 37.8 21.7 18.7 18.0
250 32.8 38.3 36.3 19.8 16.8 17.3

Cat6 SF/UTP

CONSTRUCTION PARAMETERS

Cable Code Construction No. of elements×No. of cores in element×Conductor diameter Nominal Insulation Thickness Nominal Inner Sheath Thickness Nominal Outer Sheath Thickness Nominal Overall Diameter Nominal Weight
  mm mm mm mm mm kg/km
CAT6 U/UTP CWB 4×2×0.56/0.57 0.2 0.6 1.0 7.88 115
CAT6 U/UTP SWB 4×2×0.56/0.57 0.2 0.6 1.0 7.88 109
CAT6 U/UTP SWA 4×2×0.56/0.57 0.2 0.6 1.0 8.88 189
CAT6 F/UTP CWB 4×2×0.57/0.58 0.2 0.6 1.0 8.48 126
CAT6 F/UTP SWB 4×2×0.57/0.58 0.2 0.6 1.0 8.48 132
CAT6 F/UTP SWA 4×2×0.57/0.58 0.2 0.6 1.0 9.48 213
CAT6 SF/UTP CWB 4×2×0.57/0.58 0.2 0.6 1.0 8.96 154
CAT6 SF/UTP SWB 4×2×0.57/0.58 0.2 0.6 1.0 8.96 148
CAT6 SF/UTP SWA 4×2×0.57/0.58 0.2 0.6 1.0 9.96 242