300/500V SR Insulated & LSZH Sheathed Fire Alarm Cables

FR200P 2GSH-U (PH30) (CU/SR/OS/LSZH 300/500V Class 1)
FR200P 2GSH-R (PH30) (CU/SR/OS/LSZH 300/500V Class 2)

19 300500V SR Insulated LSZH Sheathed Fire Alarm Cables

Application:

The cables are designed, manufactured and tested as data transmission cables for emergency services. These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire.

STANDARDS:

Basic design to BS 7629-1

FIRE PERFORMANCE

Circuit Integrity

IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);

BS 8434-1 (30mins); BS 5839-1 Clause 26 2d; CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)

Circuit Integrity with mechanical shock

EN 50200(PH30); CEI 20-36/4-0

Circuit Integrity with mechanical shock & water spray

EN 50200 annex E

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame Retardance (Single Vertical

Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;

VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation

(Vertically-mounted bundled wires

& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

CABLE CONSTRUCTION 

  1. Conductors: Plain annealed copper wire, solid according to IEC(EN) 60228 class 1, stranded according to IEC(EN) 60228 class 2.
  2. Insulation: Fire resistant silicone rubber compound type EI2 as per BS 7655-1.1.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize

crosstalk. Two-pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together in concentric layers with suitable non-hygroscopic fillers.

  1. Overall screen: Aluminum/polyester tape with tinned copper drain wire.
  2. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH

compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

COLOUR CODE

Insulation Colour:

Cables up to 6 pairs black-red / black-blue / red-blue / yellow-black /yellow-red / yellow-blue

Cables above 6 pairs all pairs black-red numbered on the wrapping tape.

Sheath Colour: Colour red (other colours on request).

Physical AND THERMAL PROPERTIES

Temperature range during operation (fixed state): -30°C – +90°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 7.5 x Overall Diameter

CONSTRUCTION PARAMETERS

Cable Code

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx.

Weight

mm2

mm

mm

mm

kg/km

1 Pairs

1x2x1 FR200P 2GSH-R (PH30)

0.6

0.9

7.4

77

1x2x1.5 FR200P 2GSH-R (PH30)

0.7

0.9

8,7

100

2 Pairs

2x2x1 FR200P 2GSH-R (PH30)

0.6

1.0

10.6

130

2x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.0

10.2

188

3 Pairs

3x2x1 FR200P 2GSH-R (PH30)

0.6

1.1

11.2

196

3x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.1

12.9

223

5 Pairs

5x2x1 FR200P 2GSH-R (PH30)

0.6

1.2

13.7

245

5x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.3

16.7

346

6 Pairs

6x2x1 FR200P 2GSH-R (PH30)

0.6

1.2

14.8

300

6x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.3

17.5

426

10 Pairs

10x2x1 FR200P 2GSH-R (PH30)

0.6

1.4

18.9

378

10x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.5

23.4

541

15 Pairs

15x2x1 FR200P 2GSH-R (PH30)

0.6

1.5

23.2

567

15x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.6

28.9

892

20 Pairs

20x2x1 FR200P 2GSH-R (PH30)

0.6

1.6

26.2

831

20x2x1.5 FR200P 2GSH-R (PH30)

0.7

1.8

32.5

1182