300/500V Mica+XLPE Insulated & LSZH Sheathed Fire Alarm Cables

FR200P 05M2XSH-R (CU/MICA+XLPE/OS/LSZH 300/500V Class 2 )

20 300500V MicaXLPE Insulated LSZH Sheathed Fire Alarm Cables

Application:

The cables are designed, manufactured and tested as data transmission cables for emergency services. These are primarily intended for for indoor instrumentation and control cabling, electrically noisy environments and fire alarm systems in office buildings when high frequency signal transmission has to be assured in the event of a fire.

STANDARDS:

Basic design to BS 7629-1

FIRE PERFORMANCE

Circuit Integrity

IEC 60331-21; BS 6387 CWZ; DIN VDE 0472-814(FE180);

CEI 20-36/2-1; SS229-1; NBN C 30-004 (cat. F3); NF C32-070-2.3(CR1)

System circuit integrity

DIN 4102-12, E30 depending on lay system

Flame Retardance (Single Vertical

Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2;

VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation

(Vertically-mounted bundled wires

& cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

CABLE CONSTRUCTION 

  1. Conductors: Plain annealed copper wire, stranded according to IEC(EN) 60228 class 2.
  2. Insulation: Mica glass tape covered by extruded cross-linked XLPE compound or cross-linked

compound type EI5 as per BS 7655: section 5.1.

Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize

crosstalk. Two-pair cable had four cores laid in quad formation.

Cabling: Pairs are cabled together. In cables with 8 pairs or more, 4 pairs are assembled to form a

bunch, the bunches are then cabled together.

  1. Overall screen: Aluminum/polyester tape with tinned copper drain wire.
  2. Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH

compound type SW2-SW4 as per BS 7655-2.6 can be offered.)

COLOUR CODE

Insulation Colour: According to IEC 60189-2 (other colour code on request).

Sheath Colour: Colour red (other colours on request).

Physical AND THERMAL PROPERTIES

Temperature range during operation (fixed state): -30°C - +90°C

Temperature range during installation (mobile state): -20°C - +50°C

Minimum bending radius: 8 x Overall Diameter

CONSTRUCTION PARAMETERS

Cable Code

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Approx.

Weight

mm2

mm

mm

mm

kg/km

1 Pairs

1x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

0.8

7.8

64

1x2x1FR200P 05M2XSH-R (PH30)

0.6

0.9

8.4

73

1x2x1.5FR200P 05M2XSH-R (PH30)

0.7

0.9

9.3

87

2 Pairs

2x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

0.9

10.7

118

2x2x1 FR200P 05M2XSH-R (PH30)

0.6

1.0

11.5

136

2x2x1.5 FR200P 05M2XSH-R (PH30)

0.7

1.0

13.0

165

5 Pairs

5x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

1.1

14.8

218

5x2x1 FR200P 05M2XSH-R (PH30)

0.6

1.2

15.7

266

5x2x1.5 FR200P 05M2XSH-R (PH30)

0.7

1.3

18.1

342

10 Pairs

10x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

1.3

20.1

380

10x2x1 FR200P 05M2XSH-R (PH30)

0.6

1.4

21.3

455

10x2x1.5 FR200P 05M2XSH-R (PH30)

0.7

1.5

24.8

606

15 Pairs

15x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

1.4

24.9

535

15x2x1 FR200P 05M2XSH-R (PH30)

0.6

1.5

26.5

646

15x2x1.5 FR200P 05M2XSH-R (PH30)

0.7

1.6

30.8

862

20 Pairs

20x2x0.75 FR200P 05M2XSH-R (PH30)

0.6

1.5

28.2

680

20x2x1 FR200P 05M2XSH-R (PH30)

0.6

1.6

30.2

839

20x2x1.5 FR200P 05M2XSH-R (PH30)

0.7

1.8

34.9

112