XLPE Insulated, LSZH sheathed & overall screened Instrumentation cables (Multipair)

RE-2X(st)H 90°c / 300V

XLPE Insulated LSZH sheathed overall screened Instrumentation cables Multipair

STANDARDS Basic design to EN 50288-7
APPLICATION Instrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.
The unarmoured LSZH sheathed cables are generally use for indoor installation and suitable for wet and damp areas. Generally, the cables are used within industrial process manufacturing plants for communication, data and voice transmission signals and services. Also used for the interconnection of electrical equipment and instruments, the LSZH sheath can reduce toxic smoke and fume emission.

FIRE PERFORMANCE

Flame Retardance (Single Vertical

Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE

0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation

(Vertically-mounted bundled wires

& cable test)***

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Sunlight Resistance

UL 1581 section 1200

Oil Resistance**

ICEA S-73-532

Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.

VOLTAGE RATING 300V
CABLE CONSTRUCTION  
Conductor: Annealed copper solid or plain copper stranded to IEC 60228 Class 2.
Insulation: Extruded cross-linked XLPE compound, EN 50290. 2-29.
Pairs: Two insulated conductors uniformly twisted together with a lay not exceeding 100mm
Binder tape: PETP transparent tape
Overall Screen: Aluminium/polyester tape is applied over the laid up pairs metallic side down in contact with tinned copper drain wire, 0.5mm²
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.
COLOUR CODE  
Insulation: Black / White, continuously numbered on white core(1, 2..)for multipair.
Outer Sheath: Black or blue for intrinsically safe systems
Physical AND THERMAL PROPERTIES  
Temperature Range During Operation (Fixed State): -30°C – +90°C
Temperature Range During Installation (Mobile State): -5°C – +50°C
Minimum Bending Radius: 7.5 X Overall Diameter

CONSTRUCTION PARAMETERS

 Cable Code

RE-2X(St)H

No. of Pairs

x2xCross Section

Nominal

Insulation

Thickness

Nominal

Outer Sheath

Thickness

Nominal

Overall

Diameter

Approx.

Weight

 

No.x2xmm2

mm

mm

mm

kg/km

0.5mm2, Multipair

RE-2X(St)H 2P0.5

2x2x0.5

0.35

0.9

7.6

66

RE-2X(St)H 4P0.5

3x2x0.5

0.35

0.9

8.8

98

RE-2X(St)H 5P0.5

4x2x0.5

0.35

1.0

9.8

112

RE-2X(St)H 6P0.5

5x2x0.5

0.35

1.0

10.6

133

RE-2X(St)H 8P0.5

8x2x0.5

0.35

1.0

11.3

161

RE-2X(St)H 10P0.5

10x2x0.5

0.35

1.1

12.9

200

RE-2X(St)H 12P0.5

12x2x0.5

0.35

1.1

13.5

242

RE-2X(St)H 16P0.5

16x2x0.5

0.35

1.1

15.2

288

RE-2X(St)H 20P0.5

20x2x0.5

0.35

1.2

16.9

376

RE-2X(St)H 24P0.5

24x2x0.5

0.35

1.2

18.3

426

0.75mm2, Multipair

RE-2X(St)H 2P0.75

2x2x0.75

0.38

0.9

8.5

87

RE-2X(St)H 4P0.75

3x2x0.75

0.38

1.0

10.0

122

RE-2X(St)H 5P0.75

4x2x0.75

0.38

1.0

10.9

154

RE-2X(St)H 6P0.75

5x2x0.75

0.38

1.0

11.8

174

RE-2X(St)H 8P0.75

8x2x0.75

0.38

1.1

12.8

213

RE-2X(St)H 10P0.75

10x2x0.75

0.38

1.1

14.5

266

RE-2X(St)H 12P0.75

12x2x0.75

0.38

1.1

15.1

304

RE-2X(St)H 16P0.75

16x2x0.75

0.38

1.2

17.3

398

RE-2X(St)H 20P0.75

20x2x0.75

0.38

1.3

19.2

478

RE-2X(St)H 24P0.75

24x2x0.75

0.38

1.3

20.8

559

1.0mm2, Multipair

RE-2X(St)H 2P1.0

2x2x1.0

0.4

0.9

9.2

101

RE-2X(St)H 4P1.0

3x2x1.0

0.4

1.0

10.9

157

RE-2X(St)H 5P1.0

4x2x1.0

0.4

1.0

11.9

194

RE-2X(St)H 6P1.0

5x2x1.0

0.4

1.0

13.0

223

RE-2X(St)H 8P1.0

8x2x1.0

0.4

1.1

14.0

272

RE-2X(St)H 10P1.0

10x2x1.0

0.4

1.1

15.9

334

RE-2X(St)H 12P1.0

12x2x1.0

0.4

1.2

16.8

390

RE-2X(St)H 16P1.0

16x2x1.0

0.4

1.2

19.0

511

RE-2X(St)H 20P1.0

20x2x1.0

0.4

1.3

21.1

617

RE-2X(St)H 24P1.0

24x2x1.0

0.4

1.4

23.1

749

1.3mm2, Multipair

RE-2X(St)H 2P1.3

2x2x1.3

0.45

1.0

10.4

124

RE-2X(St)H 4P1.3

3x2x1.3

0.45

1.0

12.0

184

RE-2X(St)H 5P1.3

4x2x1.3

0.45

1.1

13.4

226

RE-2X(St)H 6P1.3

5x2x1.3

0.45

1.1

14.6

289

RE-2X(St)H 8P1.3

8x2x1.3

0.45

1.2

15.7

337

RE-2X(St)H 10P1.3

10x2x1.3

0.45

1.2

17.9

411

RE-2X(St)H 12P1.3

12x2x1.3

0.45

1.3

18.9

495

RE-2X(St)H 16P1.3

16x2x1.3

0.45

1.3

21.4

651

RE-2X(St)H 20P1.3

20x2x1.3

0.45

1.4

23.8

772

RE-2X(St)H 24P1.3

24x2x1.3

0.45

1.5

25.9

933

1.5mm2, Multipair

RE-2X(St)H 2P1.5

2x2x1.5

0.45

1.0

10.8

139*

RE-2X(St)H 4P1.5

3x2x1.5

0.45

1.1

12.7

214

RE-2X(St)H 5P1.5

4x2x1.5

0.45

1.1

14.0

259

RE-2X(St)H 6P1.5

5x2x1.5

0.45

1.2

15.2

305

RE-2X(St)H 8P1.5

8x2x1.5

0.45

1.2

16.4

385

RE-2X(St)H 10P1.5

10x2x1.5

0.45

1.3

18.8

460

RE-2X(St)H 12P1.5

12x2x1.5

0.45

1.3

19.7

558

RE-2X(St)H 16P1.5

16x2x1.5

0.45

1.4

22.5

725

RE-2X(St)H 20P1.5

20x2x1.5

0.45

1.5

25.0

881

RE-2X(St)H 24P1.5

24x2x1.5

0.45

1.5

27.1

147

Note : Other conductor sizes & core configurations are available upon request.

Electrical PROPERTIES

Conductor Area Size

mm 2

0.5

0.75

1.0

1.3

1.5

Insulation thickness (nominal)

mm

0.35

0.38

0.4

0.45

0.45

Conductor resistance (20°C)

Ω/km

36.7

25

18.5

14.2

12.3

Insulation resistance (20°C)

MΩ.km(Min.)

5000

Mutual Capacitance (1 kHz)

pF/m(Max.)

 
 

≤ 4 pairs

90

90

90

102

102

 

all other pairs

75

75

75

85

85

Capacitance unbalance(1 kHz)

pF/500 m (Max.)

500

Inductance

mH/km (Max.)

1

L / R (ratio) (max.)

μH/Ω

25

25

25

40

40

Operating voltage Urms

V

300

Test Voltage

Core to Core

V

1500

Core to Screen

V

1500