XDSL Connecting Cables

XDSL Connecting Cables

Application The cables are designed for XDSL transmission system. The cables are characterized by guaranteed data speeds up to 40MHz.
Standards ER.f5.113
Construction
Conductors:  Solid annealed bare copper sized 0.5mm as per ASTM B-3/IEC 60228 Class1
Insulation:  Solid polyethylene as per ASTM D 1248/IEC 60708
Twisted Pairs: Insulated conductors are twisted into pairs with varying lays to minimize crosstalk
Cable Core Assembly: The pairs are cabled together in layers of 12, 13 & 25 pair unit to form the cable core. Units are identified by colour coded binders.
Core Wrapping: One or more non-hygroscopic polyester tapes are helically or longitudinally laid with an overlap
Screen: An aluminium polyster foil is applied longitudinally with an overlap
Sheath: Black low density polyethylene as per BS 6234/IEC 60708
Ripcord: Nylon ripcord may be placed parallel to the cores to facilitate sheath removal

Electrical Properties

Conductor Diameter

mm

0.5

Maximum Conductor Resistance @20°C

Ω/km

91

Minimum Insulation Resistance @500V DC

MΩ.km

20000

Maximum Resistance Unbalance

%

2

Average Mutual Capacitance

nF/km

52

Maximum Capacitance Unbalance @1KHz pair-to-pair

pF/500m

45

Maximum Capacitance Unbalance @1KHz pair-to-ground

pF/500m

400

Impedance @0.3 – 1MHz

100+/- 20

Impedance @1 – 40MHz

100+/- 15

Maximum Average Attenuation @0.1MHz

dB/km

0.81

Maximum Average  Attenuation @0.3MHz

dB/km

1.15

Maximum Average Attenuation @0.6MHz

dB/km

1.65

Maximum Average Attenuation @1MHz

dB/km

2.1

Maximum Average  Attenuation @4MHz

dB/km

4.3

Maximum Average Attenuation @10MHz

dB/km

6.6

Maximum Average Attenuation @16MHz

dB/km

8.2

Maximum Average Attenuation @20MHz

dB/km

9.2

Maximum Average Attenuation @31.25MHz

dB/km

11.8

Maximum Average Attenuation @40MHz

dB/km

13.9

Minimum Return Loss @1-20MHz

dB/100m

23

Minimum Return Loss @20-40MHz

dB/km

23-10log (f/20)

Minimum ELFEXT pair-to-pair @0.16MHz

dB

69

Minimum ELFEXT pair-to-pair @1MHz

dB

55

Minimum ELFEXT pair-to-pair @20MHz

dB

29

Minimum ELFEXT pair-to-pair @40MHz

dB

23

Minimum NEXT pair-to-pair @0.16MHz

dB

68

Minimum NEXT pair-to-pair @1MHz

dB

59

Minimum NEXT pair-to-pair @20MHz

dB

39

Minimum NEXT pair-to-pair @40MHz

dB

35

Dielectric Strength

dB

 

Conductor to Conductor 3secs

V DC

3000

Conductor to Screen 3secs

V DC

5000

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C 

Minimum bending radius: 10 x Overall Diameter

Colour Code

Standard colour code is per ANSI/ICEA S-80-576 given in Colour Code Chart.

Dimensions And Weight

Cable Code

Number 

of 

Pairs/Quads

Nominal Insulation 

Thickness mm

Nominal Sheath 

Thickness mm

Nominal Overall 

Diameter 

mm

Nominal Weight kg/km

UE-TP113-2Y(St)Y-26P05-XDSL

26

0.2

0.9

18.5

265

UE-TP113-2Y(St)Y-51P05-XDSL

51

0.2

1.0

24.2

460

UE-TP113-2Y(St)Y-101P05-XDSL

101

0.2

1.1

31.5

790

UE-TP113-2Y(St)Y-202P05-XDSL

202

0.2

1.2

41.5

1415