Application | These Cat7 S/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class F applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for voice, data, CATV and sharing application installations up to 600MHz. |
Standards | EN 50173-1 EN 50288-4-1 ISO/IEC 11801 IEC 61156-5 IEC 60332-1 (for LSOH & FRLSOH Sheath) IEC 60754-2 (for LSOH & FRLSOH Sheath) IEC 61034 (for LSOH & FRLSOH Sheath) IEC 60332-3-24 (for FRLSOH Sheath) |
Construction | |
Conductors | Solid bare copper conductor. |
Insulation | Foam skin PE. |
Twinning | Two coloured insulated conductors twisted together to form a pair. |
Individual Screen | Al/polyester tape. |
Overall Screen | Tinned copper wire braid. |
Outer Sheath | LSOH/FRLSOH. |
Core Identification | Pair 1: White, Blue Pair 2: White, Orange Pair 3: White, Green Pair 4: White, Brown |
Electrical Properties
Maximum Loop Resistance |
Ω/km |
165 |
Maximum Resistance Unbalance |
|
2% |
Minimum Insulation Resistance (500V) |
MΩ.km |
2000 |
Nominal Mutual Capacitance @800Hz |
nF/km |
43 |
Maximum Capacitance Unbalance (pair to ground) |
pF/km |
1500 |
Characteristic Impedance @1-100MHz |
Ω |
100 ± 5 |
Nominal Velocity of Propagation |
|
ca. 79% |
Maximum Propagation Delay |
ns/100 m |
427 |
Maximum Delay Skew |
ns/100 m |
12 |
Maximum Transfer Impedance @1MHz |
mΩ /m |
5 |
Maximum Transfer Impedance @10MHz |
mΩ /m |
5 |
Maximum Transfer Impedance @30MHz |
mΩ /m |
10 |
Minimum Coupling Attenuation |
dB |
85 |
Nominal Transmission Characteristics @20℃
F |
Attenuation |
NEXT |
PS-NEXT |
ACR |
PS-ACR |
ELFEXT |
PS-ELFEXT |
Return Loss |
MHz |
dB/100m |
dB |
dB |
dB/100m |
dB/100m |
dB/100m |
dB/100m |
dB |
1 |
1.8 |
100 |
97 |
98 |
95 |
105 |
105 |
20.5 |
4 |
3.4 |
100 |
97 |
97 |
94 |
105 |
102 |
27 |
10 |
5.4 |
100 |
97 |
95 |
92 |
97 |
94 |
30 |
16 |
6.8 |
100 |
97 |
93 |
90 |
93 |
90 |
30 |
20 |
7.7 |
100 |
97 |
92 |
89 |
91 |
88 |
30 |
31.2 |
9.6 |
100 |
97 |
90 |
87 |
87 |
84 |
30 |
62.5 |
13.7 |
100 |
97 |
86 |
83 |
81 |
78 |
30 |
100 |
17.4 |
100 |
97 |
83 |
80 |
77 |
74 |
30 |
125.0 |
19.5 |
95 |
92 |
75 |
72 |
75 |
72 |
26 |
155.5 |
21.9 |
94 |
91 |
72 |
69 |
73 |
70 |
26 |
175.0 |
23.3 |
93 |
90 |
70 |
67 |
72 |
69 |
25 |
200.0 |
25.0 |
92 |
89 |
67 |
64 |
71 |
68 |
25 |
250.0 |
28.1 |
90 |
87 |
62 |
59 |
69 |
66 |
24 |
300.0 |
30.9 |
89 |
86 |
58 |
55 |
67 |
64 |
24 |
450.0 |
38.3 |
87 |
84 |
48 |
45 |
64 |
61 |
23 |
600.0 |
44.8 |
85 |
82 |
40 |
37 |
61 |
58 |
22 |
750.0 |
52.0 |
83 |
80 |
31 |
28 |
59 |
56 |
21 |
900.0 |
59.4 |
82 |
79 |
23 |
20 |
58 |
55 |
20 |
1000.0 |
63.1 |
80 |
77 |
17 |
14 |
57 |
54 |
20 |
Mechanical and Thermal Properties
Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
Temperature Range: -20℃ ~ +60℃
Dimensions and Weight
Part No. |
Construction No. of elements×No. of cores in element×Cross section(mm²) |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
UE092-S/FTPCAT74P23 |
4×2×23AWG |
0.41 |
0.75 |
7.5 |
75 |
UE092-S/FTPCAT78P23 |
2×(4×2×23AWG) |
0.41 |
0.75 |
7.5×15.0 |
150 |