Application | These profibus cables are dedicated for fixed installation on board of ship, used as connection cables for digital signals up to 12MBd. |
Standards | IEC 60332-1&2 IEC 60754-1/2 IEC 61034 IEC 60092 |
Construction | |
Conductors | Stranded bare copper 22 AWG. |
Insulation | Foam skin PE. |
Inner Sheath | Thermoplastic copolymer (FRNC). |
Overall Screen1 | Aluminium/polyester tape. |
Overall Screen2 | Tinned copper braid. |
Outer Sheath | SHF2. |
Core Identification | Core 1: Red Core 2: Green |
Electrical Characteristics
Characteristic Impedance |
Ω |
150 ± 15 |
Mutual Capacitance @1KHz |
nF/km |
28.5 |
Insulation Resistance |
MΩ.km |
16000 |
Attenuation @9.6kHz |
dB/km |
2.5 |
Attenuation @38.4kHz |
dB/km |
4 |
Attenuation @4kHz |
dB/km |
22 |
Attenuation @16kHz |
dB/km |
42 |
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 10×OD
Temperature Range: -25℃ ~ +80℃
Dimensions and Weight
Part No. |
Construction No. of elements×No. of cores in element×Cross section(mm²) |
Core Diameter mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
UE092- 02YSH(ST)CH-1×2×22A |
1×2×22 AWG |
2.55 |
8.0 |
84 |