Construction
| Inner conductor | Tinned copper | 7 x 0.25 mm | 
 | 
| Dielectric | Foam PE | Φ2.00 ± 0.10 mm | |
| Outer conductor (shield 1) | Aluminium+polyester+Al tape | 
 | |
| Shield coverage | 
 | 100% | |
| Outer conductor (shield 2) | Tinned copper | 48 x 0.12 mm | |
| Shield coverage | 
 | 64% | |
| Sheath | PVC or LSZH | Φ3.60 ± 0.10 mm | 
Electrical & Mechanical Characteristics
| Impedance | 50±3 Ohm | 
| Nominal capacitance | 95pF/m | 
| Velocity of propagation | 75% | 
| Insulation resistance | >5000 Mohm.Km | 
| Inner conductor resistance | 20.5 Ohm/Km | 
| Outer conductor resistance | 32.5 Ohm/Km | 
| Operating temperature range | -30 °C - +70 °C | 
| Copper weight | 8.2 Kg/Km | 
| Cable weight (approx.) | 18.3 Kg/Km | 
| Screening effectiveness | >75 dB | 
Attenuation
| Frequency (MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) | 
| 100 | 17.3 | 5.27 | 
| 400 | 35 | 10.67 | 
| 600 | 43.3 | 13.2 | 
| 860 | 52.7 | 16.07 | 
| 1000 | 57.2 | 17.44 | 
| 1750 | 76.7 | 23.38 | 
| 2400 | 94 | 28.66 | 
Return Loss
| 30-300 MHz | >24dB | 
| 300-600 MHz | >21dB | 
| 600-900 MHz | >15dB | 

 
	