Construction
| Inner conductor | Plain copper | 2.5 mm | 
 | 
| Dielectric | Aired PE | Φ6.90 ± 0.20 mm | |
| Outer conductor (shield1 ) | Copper + polyester tape | 
 | |
| Shield coverage | 
 | 100% | |
| Outer conductor (shield 2) | Plain copper | 96 x 0.12 mm | |
| Shield coverage | 
 | 50% | |
| Sheath | PVC or LSZH | Φ9.70 ± 0.20 mm | 
Electrical & Mechanical Characteristics
| Impedance | 50±3 Ohm | 
| Nominal capacitance | 80 pF/m | 
| Velocity of propagation | 84% | 
| Insulation resistance | >5000 Mohm.Km | 
| Inner conductor resistance | 3.7 Ohm/Km | 
| Outer conductor resistance | 12.5 Ohm/Km | 
| Operating temperature range | -30 °C - +70 °C | 
| Copper weight | 61.0 Kg/Km | 
| Cable weight (approx.) | 128.4 Kg/Km | 
| Screening effectiveness | >75 dB | 
Attenuation
| Frequency(MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) | 
| 50 | 2.5 | 0.76 | 
| 100 | 3.6 | 1.1 | 
| 400 | 7.9 | 2.41 | 
| 600 | 10.1 | 3.08 | 
| 860 | 12.1 | 3.69 | 
| 1000 | 13.2 | 4.02 | 
| 1750 | 18.7 | 5.7 | 
| 2400 | 22.2 | 6.77 | 
Return Loss
| 30-300 MHz | >25dB | 
| 300-600 MHz | >22dB | 
| 600-900 MHz | >18dB | 

 
	