Type W Two-Conductor Flat Portable Power Cable 2kV

Type W Two Conductor Flat Portable Power Cable 2kV

Applications These flat parallel cables are designed for use on DCmining equipment, such as D.C. shuttle cars, drills, cutting and loading machines.
Standards ICEA S-75-381/NEMA WC 58
ASTM B 172
ASTM B 33
CAN/CSA C22.2 No. 96
Construction
Conductors Stranded annealed tinned copper conductor.
Insulation Ethylene Propylene Rubber (EPR).
Reinforcement Synthetic yarn.
Jacket Heavy-duty/extra-heavy-duty Chlorinated Polyethylene (CPE), black. (Cables having a nominal outside diameter of more than 2.0 inches require extra-heavy-duty jackets.)
Options Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties Minimum Bending Radius: 6×OD
Maximum Operating Temperature: +90℃

Dimensions and Weight:

Construction

No. of Strands

Nominal Insulation Thickness

Nominal Jacket

Thickness

Nominal Overall Diameter

Height×Width

Nominal Weight

Ampacity

No. of cores×AWG/kcmil

 

inch

mm

inch

mm

inch

mm

lbs/kft

kg/km

A

2×8

133

0.06

1.5

0.080

2.0

0.51×0.84

13.0×21.3

340

506

72

2×6

133

0.06

1.5

0.080

2.0

0.56×0.93

14.2×23.6

440

655

95

2×4

259

0.06

1.5

0.095

2.4

0.61×1.05

15.5×26.7

550

818

127

2×3

259

0.06

1.5

0.095

2.4

0.68×1.14

17.3×29.0

675

1005

145

2×2

259

0.06

1.5

0.095

2.4

0.73×1.24

18.5×31.5

810

1205

167

2×1

259

0.08

2.0

0.110

2.8

0.81×1.40

20.6×35.6

1020

1520

191

2×1/0

259

0.08

2.0

0.125

3.2

0.93×1.51

23.6×38.2

1265

1880

217

2×2/0

329

0.08

2.0

0.125

3.2

0.99×1.63

25.1×41.4

1515

2255

250

2×3/0

413

0.08

2.0

0.140

3.6

1.03×1.77

26.2×45.0

1810

2694

286

2×4/0

532

0.08

2.0

0.140

3.6

1.10×1.89

27.9×48.0

2175

3237

328

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.