(N)SSHOEU 0.6/1kV Heavy Duty Flexible Cable VDE 0250 Part 812

NSSHOEU 0.61kV Heavy Duty Flexible Cable

Applications These cables are used for connection of mobileequipment and machines under very high mechanicalloads in dry and damp areas, outdoors and in explosionhazard areas, particularly in mining and at quarries andbuilding sites.
Standards Based on VDE 0250 Part 812
Construction
Conductors Flexible stranded copper conductor, class 5 according to DIN VDE 0295. 
Insulation Rubber type 3GI3.
Pilot Cores (optional) Tinned copper conductor with EPR insulation. 
Earth Conductor Spiral of tinnedcopper wires.
InnerSheath Rubber type GM1b.
Outer Sheath Rubber type 5GM5.

Dimensions and Weight

Number of Cores×Nominal Cross Section

Minimium Overall Diameter

Maximum Overall Diameter

Nominal Weight

No. ×mm²

mm

mm

kg/km

3x2.5+3x2.5/3E

14.0

17.0

300

3x6+3x6/3E

18.0

21.0

580

3x10+3x10/3E

21.0

25.0

860

3x2.5+3x2.5/3E+3x1.5

17.0

20.0

450

3x6+3x6/3E+3x1.5

18.0

22.0

660

3x10+3x10/3E+3x2.5

21.0

26.0

950

3x25+3x16/3E+3x2.5

28.0

33.0

1660

3x35+3x16/3E+3x2.5

30.0

35.0

1970

3x50+3x25/3E+3x2.5

36.0

41.0

2840

3x70+3x35/3E+3x2.5

41.0

46.0

3700

3x95+3x50/3E+3x2.5

47.0

52.0

4950

3x120+3x70/3E+3x2.5

52.0

57.0

5650

3x150+3x70/3E+3x2.5

58.0

63.0

6520