Multicore Overall Screened Cables-Belden Equivalent 8618,UL20253

Applications These multicore overall screened cables have individually insulated cores laid up in an aluminum/polyester tape with a tinned copper drain wire. These cables are suitable for used as audio, control and instrumentation cables.
Construction
Conductor Tinned copper wire.
Insulation PE
Overall Screen Aluminium/Polyester tape.
Drain Wire Tinned copper wire.
Sheath PVC (V type)/LSZH (H type).
Insulation Colour Black, Red, Clear.

Electrical & Mechanical Characteristics

AWG

 

18

Conductor Construction

 

19x0.287

UL Style

 

20253

Maximum Conductor Resistance

Ω/km

15.8

Voltage Rating

V

600

Nominal Capacitance Conductor to Conductor

pF/m

85

Nominal Capacitance Conductor to Screen

pF/m

164

Bending Radius

 

10xOverall Diameter

Operating Temperature

-20~60

Dimensions

Part No.

No. of Cores

Insulation Thickness

Sheath Thickness

Overall Diameter

 

 

mm

mm

mm

UEBE 8618V

3

0.79

0.79

8.3

UEBE 8618H

3

0.79

0.79

8.3