Multipair Overall Screened Cables-Belden Equivalent 8451

Applications These multipair overall screened cables have pairs laid up in an aluminum/polyester tape with a tinned copper drain wire. These cables are suitable for used as audio, control and instrumentation cables.
Construction
Conductor Tinned copper wire.
Insulation PE
Two cores twisted into pairs.
Drain Wire Tinned copper wire.
Overall Screen Aluminium/Polyester tape.
Sheath PVC (V type)/LSZH (H type).
Insulation Colour Black, Red.

Electrical & Mechanical Characteristics

AWG

 

22

Conductor Construction

 

7x0.254

Maximum Conductor Resistance

Ω/km

54.8

Voltage Rating

V

300

Nominal Capacitance Conductor to Conductor

pF/m

112

Nominal Capacitance Conductor to Screen

pF/m

220

Bending Radius

 

10xOverall Diameter

Operating Temperature

-20~75

Dimensions

Part No.

No. of Pairs

Insulation Thickness

Sheath Thickness

Overall Diameter

 

 

mm

mm

mm

UEBE 8451V

1

0.2

0.5

3.5

UEBE 8451H

1

0.2

0.5

3.5