Applications | These multipair overall screened armoured cables provide excellent protections. They are ACIC armoured cables, used as instrumentation cables. |
Construction | |
Conductor | Bare copper wire. |
Insulation | XLPE. |
Two cores twisted into pairs. | |
Overall Screen | Aluminium/ Polyester tape. |
Drain Wire | 20 AWG (7X28) tinned copper wire. |
Inner Sheath | FR PVC. |
Armour | Steel wire armour |
Outer Sheath | FR PVC |
Insulation Colour | Black, Red. Other colours are available upon your request. |
Electrical & Mechanical Characteristics
AWG |
|
18 |
Conductor Construction |
|
7x26 |
Maximum Conductor Resistance@20℃ |
Ω/km |
22 |
Nominal Outer Shield DC Resistance @ 20℃ |
Ω/km |
33 |
Voltage Rating |
V |
300 |
Bending Radius |
|
12xOverall Diameter |
Operating Temperature |
℃ |
40~90 |
Dimensions
Part No. |
No. of Pairs |
Insulation Thickness |
Sheath Thickness |
Overall Diameter |
|
|
mm |
mm |
mm |
UEBE 26514V SWA |
1 |
0.7 |
1.5 |
12.64±1 |