PVC Insulated Jumper Wires to IEC 60189-1

PVC Insulated Jumper Wires to IEC 60189 1

Application The jumper wires are used for interconnection between terminal blocks at main distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or boxes.
Standards IEC 60189-1
IEC 60332-1
UL1581 Sec.VW-1
Construction
Conductors:  Solid annealed tinned copper 0.5/0.6/0.8mm as per IEC 60228 Class 1
Insulation:  PVC
Twisted Pairs: Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Electrical & Mechanical Properties

Nominal Conductor Diameter

mm

0.5

0.6

0.8

Conductor Size

mm2

0.196

0.283

0.5

Maximum Conductor Resistance @20°C

Ω/km

98

66

35

Minimum Insulation Resistance @500V DC

MΩ.km

50

50

50

Nominal Insulation Thickness

mm

0.225

0.225

0.275

Nominal Insulated Conductor Diameter

mm

0.95

1.05

1.35

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C

Temperature range during installation (mobile state): -20°C – +50°C

Minimum bending radius: 7.5 x Overall Diameter

Color Code

Standard colour code is per IEC 60189-1

Dimensions And Weight

Cable Code

Number of Wires

Nominal Insulation 

Thickness mm

Maximum Overall Diameter 

mm

Nominal Weight kg/km

0.5mm Conductor, 0.95mm Insulated Wire

UE-TC189-Y-1W05

1

0.225

1.25

2.5

UE-TC189-Y-2W05

2

0.225

1.95

5.0

UE-TC189-Y-3W05

3

0.225

2.25

7.5

UE-TC189-Y-4W05

4

0.225

2.40

10.0

UE-TC189-Y-5W05

5

0.225

2.60

12.5

0.6mm Conductor, 1.05mm Insulated Wire

UE-TC189-Y-1W06

1

0.225

1.45

3.0

UE-TC189-Y-2W06

2

0.225

2.15

6.0

UE-TC189-Y-3W06

3

0.225

3.0

9.0

UE-TC189-Y-4W06

4

0.225

3.4

12.0

0.8mm Conductor, 1.35mm Insulated Wire

UE-TC189-Y-1W08

1

0.275

2.05

5.8

UE-TC189-Y-2W08

2

0.275

2.75

11.6

UE-TC189-Y-3W08

3

0.275

3.7

17.4

UE-TC189-Y-4W08

4

0.275

4.2

23.2