Applications | These cables are designed for useas flexible welding leads connecting the electrode holder to the welding machine in the secondary circuit of electric arc welding systems. |
Standards | ICEA S-75-381/NEMA WC 58 ASTM B 172 ASTM B 33 CAN/CSA C22.2 No. 96 UL 1581 |
Construction | |
Conductors | Class K/M stranded annealed copper conductor. |
Jacket | Heavy-duty/medium-duty Ethylene Propylene Rubber (EPR). |
Options | Other jacket materials such as CSP/PCP/NBR/PVC are available upon request. Two-layer jacket with reinforcing fibre between the two layers can be offered as an option. |
Mechanical and Thermal Properties | Minimum Bending Radius: 6×OD Maximum Operating Temperature: +90℃ |
Dimensions and Weight:
Construction |
No. of Strands |
Nominal Insulation Thickness |
Nominal Overall Diameter |
Nominal Weight |
Ampacity |
|||
No. of cores×AWG/kcmil |
- |
inch |
mm |
inch |
mm |
lbs/kft |
kg/km |
A |
1×6 |
259 |
0.060 |
1.5 |
0.37 |
9.4 |
124 |
184 |
125 |
1×4 |
420 |
0.060 |
1.5 |
0.42 |
10.7 |
180 |
268 |
182 |
1×2 |
665 |
0.060 |
1.5 |
0.49 |
12.5 |
268 |
399 |
271 |
1×1 |
836 |
0.080 |
2.0 |
0.53 |
13.3 |
319 |
475 |
360 |
1×1/0 |
1045 |
0.080 |
2.0 |
0.59 |
14.9 |
415 |
617 |
444 |
1×2/0 |
1330 |
0.080 |
2.0 |
0.64 |
16.3 |
508 |
756 |
535 |
1×3/0 |
1672 |
0.080 |
2.0 |
0.70 |
17.8 |
628 |
934 |
667 |
1×4/0 |
2107 |
0.080 |
2.0 |
0.81 |
20.7 |
775 |
1153 |
809 |
1×250 |
2499 |
0.095 |
2.4 |
0.88 |
22.4 |
934 |
1390 |
1048 |
1×350 |
3458 |
0.095 |
2.4 |
1.01 |
25.6 |
1267 |
1885 |
1396 |
1×500 |
5054 |
0.095 |
2.4 |
1.18 |
30.0 |
1801 |
2680 |
1973 |