CU/XLPE/LSZH/CT/LSZH/AWA/LSZH (Single Cores)
XLPE Insulated, LSZH Bedded, Copper Tape Screened, LSZH Sheathed, Aluminium Wire Armoured,
LSZH Sheathed Cable

 

Application

These power cable for fixed installations such as distribution networks or industrial installations.
Such as Plant engineering; Industrial machinery; Heating and air-conditioning systems; Power stations; Stage applications etc.
Armoured cable suitable for direct burial.

1core insulation bedding screen separation sheath armour sheath

Construction

Conductor: Plain annealed copper, class1 solid or class 2 stranded acc. to IEC 60228.
                 Flexible class 5 or tinned conductor could be offer upon request.
Insulation: Cross-linked polyethlene (XLPE) compound as per IEC 60502-1.
Insulation Color Code:

Number of Cores Color Code to IEC 60502-1
1 Natural

Bedding: Low smoke zero halogen (LSZH) compound type ST8 (90°C) of IEC 60502-1.
Bedding Color: Black.
Screen: Copper tape.
Separation Sheath: Low smoke zero halogen (LSZH) compound type ST8 (90°C) of IEC 60502-1.
Separation Sheath Color: Black.
Armour: Aluminium wire armoured (AWA).
Outer Sheath: Low smoke zero halogen (LSZH) compound type ST8 (90°C) of IEC 60502-1.
Outer Sheath Color: Black or other color as per customer request.

 

Electrical Characteristics

Recommended rated voltages U0

Highest system voltage
(Um) (kV)
Rated voltage (U0) (kV)
Categories A and B Category C
1,2 0,6 0,6

Routine test voltages

Rated voltage U0 (kV) 0,6
Test voltage (kV) 3,5

Maximum conductor temperatures for different types of insulating compound

Maximum conductor temperature (°C)
Normal operation Short-circuit (5 s maximum duration)
90 250

Operating Temperature: -15°C to 90°C
Test Voltage: 3.5 kV for 5 minutes

 

Installation Reference

Min.Bending Radius (mm): 8 x cable overall diameter
Max.Pulling Tension (N/mm2): 50

 

Reference Standards

Design Specification: IEC60502-1
Conductor: IEC60228, BS EN60228
Flame Retardancy: IEC60332-3-22, BS EN60332-3-22
Low Smoke Zero Halogen: IEC61034-2, BS EN61034-2, IEC60754-1, IEC60754-2, BS EN50267-2-1, BS EN50267-2-2

 

Dimension

Nominal Conductor Area(mm2) No.and Diameter of Wires
(no./mm)
Thickness of Insulation
(mm)
Diameter Under Screen
(mm)
Diameter Under Armour
(mm)
Armour Wire Diameter
(mm)
Overall Diameter
(mm)
Approximate Weight
(kg/km)
1x70 19/2.14 1.1 15.3 18.7 1.6 25.7 1677
1x95 19/2.52 1.1 17.2 20.6 1.6 27.6 2111
1x120 37/2.03 1.2 19 22.4 1.6 29.4 2463
1x150 37/2.25 1.4 21 24.6 1.6 31.4 2846
1x185 37/2.52 1.6 23.2 26.8 1.6 34 3533
1x240 61/2.25 1.7 26.1 29.7 2 37.9 4383
1x300 61/2.52 1.8 28.7 32.3 2 40.7 5181
1x400 61/2.85 2 32.5 36.1 2 44.7 6317
1x500 61/3.20 2.2 36 39.6 2 48.4 7578
1x630 127/2.52 2.4 40.4 44.2 2.5 54.4 9505
1x800 127/2.85 2.6 45.5 49.5 2.5 59.9 11694
1x1000 127/3.20 2.8 50.4 54.6 2.5 65.4 14193

 