FLRYBY FLRYCY Connecting Cable with Improved EMC for Cars and Other Vehicles

multi core shield

 

Automotive Cables Product Photos 004

FLRYBY FLRYCY Connecting Cable with Improved EMC for Cars and Other Vehicles

 

FLRYBY Automotive Wire:

Nominal Cross-Section (mm2): 1×0.35 / 4×0.35  etc.

Diameter of Conductor (mm): 0.8 / 0.8  etc.

 

FLRYCY Automotive Wire:

Nominal Cross-Section (mm2): 9×0.05 / 10×0.25 / 5×0.35 / 8×0.35 / 10×0.35 etc.

Diameter of Conductor (mm): 0.45 / 0.7 / 0.8 / 0.8 / 0.8  etc.

 

Color: Green/Yellow/White/Brown/Black/Red etc.

 

FLRYBY/FLRYCY Automotive Wire: Standard/Specification

ISO 6722

 

FLRYBY/FLRYCY Automotive Wire: Application

Connecting cable with improved EMC for cars and other vehicles

 

Lead Time:  Quantity(Meters): 1-10000; Time(days): 10

                    Quantity(Meters): >10000;  Time(days): To be negotiated

 

Customization:

                    Customized logo(Min. Order: 3000 Meters)

                    Customized packaging(Min. Order: 3000 Meters)

 

Our Automotive ISO 6722 Cable Product :

FLY;FLRY-A;FLRY-B;FLR2X-A;FLR2X-B;FLR2X-C;FLYY;FLRY11Y;FLYW;FLR9Y-A;FLR9Y-B;

FLR6Y-A;FLR6Y-B;FLRYY;FLYZ;FLYYF;FLR4Y;FLR5Y;FLR2X11Y;FLR7Y;FLR12Y;FLR13Y;

FLR14Y;FLR51Y;FLRYW125YW;FLRYBY FLRYCY;FL4G;FL4G11Y;FLR31Y;FLU6Y;FLRYW;

FL11Y FL91Y;FL2G;3TC-D;3SC-D;FL2X;FLYK;FLRYWd;FLALRY;FL2X11Y;FLR31Y11Y;

FLALRYW ... etc.

 

Automotive Cables Product Photos 003

 

The Cable Guide

Quality Policy

Automotive Wires and Cables Product Center

Contact Us

 

 

FLRYBY/FLRYCY Automotive Wire: Construction

Conductor: Soft-annealed electrolytic copper Cu-ETP1 according to DIN EN 13602, bare or

tinned. Conductor construction according to ISO 6722.

Insulation: PVC

Drain wire: Tinned copper wire according to DIN EN13602 with PVC insulation.

Shield: Aluminium foil(B); Copper wire braiding(C). 

Sheath: PVC

 

FLRYBY/FLRYCY Automotive Wire: Product Features

Voltage rating: 60 V
Temperature range: -40 °C to +105 °C (3000 h)

 

FLRYBY/FLRYCY Automotive Wire: Technical Data

Nominal
Cross-Section
(mm2)
Strand No./Max.
Diameter
(N/mm)
Diameter of
Conductor
(mm)
Nominal Insulation
Thickness
(mm)
Thickness of sheath
(mm)
Nominal Overall
Diameter
(mm)
Conductor
Resistance
(20°C Ω/km)
Weight
Approx.
(kg/km)
FLRYBY       
1×0.35 7/0.26 0.8 0.25 0.5 3.3 54.4 14
4×0.35 7/0.26 0.8 0.25 0.5 4.7 54.4 35
FLRYCY       
9×0.05 10/0.11 0.45 0.2 0.6 4.9 365 38
10×0.25 14/0.16 0.7 0.2 0.6 6.2 86.5 68
5×0.35 19/0.16 0.8 0.25 0.5 5.1 54.4 47
8×0.35 19/0.16 0.8 0.25 0.65 6.3 54.4 75
10×0.35 19/0.16 0.8 0.25 0.65 6.9 54.4 83

 

FLRYBYFLRYCY_.pdf